• Home
  • About Railway Cables European Signalling System for Rail Industry | Electrification System for Rail Industry | Basic Design for Railway Cables | Application
  • Products
  • Applications Industry | Reference List
  • Technical Information Material Properties | Standards | Customized Products | Product Certificates | Cable Glossary | FAQ
  • News & Exhibitions
  • Download
  • Link Testing Authorities | Testing Equipment Manufacturers | Magazines | Organizations | Caledonian Corporater Website
  • Sitemap
  • Contact
  • 中文

Product List

 

Traction Cables

 

Signalling & Control Cables

 

Telecom Cables

 

Power & Control Cables

 

Databus Cables

 

High Temperature Cable

 

Coaxial Cable

 

Send an enquiry to us

 

FRA 145/S EMC Screened Multicore

Application

Multicore cable with improved fire performance and very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and fl exible application in dry, humid and wet rooms.

 

Standards

  • IEC 60754-1, EN 50267-2-1 (halogen free)
  • IEC 60754-2, EN 50267-2-2 (no corrosive gases)
  • NES 02-713, NFC 20-454 (no toxic gases)
  • IEC 61034, EN 50268-2 (low smoke density)
  • IEC 60332-1, EN 50265-2-1 (flame retardant)
  • IEC 60332-3, EN 50266-2, NF C 32-070 (non-flame propagating)
  • DIN 51900 (low fire load)

 

Construction

  • Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.
  • Insulation: Electron beam crosslinkable polyolefine copolymer.
  • Screen: Copper wire screen.
  • Sheath: Electron beam crosslinkable polyolefine copolymer.

 

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 0.50 0.75 1.0 1.5 2.5 4.0 6.0
Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39
Voltage Rating V 300/500V (≤1mm²); 450/750V (≥1.5mm²)

 

Mechanical and Thermal Properties

  • Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing)
  • Temperature Range: -55℃ ~+145℃ (Static); -40℃ ~+120℃ (Flexing)
  • Short Circuit Temperature: +280℃

 

Dimensions and Weight

No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No./mm
Nominal Insulation Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
1×0.5 16/0.20 0.5 3.7 23
2×0.5 16/0.20 0.5 5.6 45
3×0.5 16/0.20 0.5 6.1 59
4×0.5 16/0.20 0.5 6.7 72
5×0.5 16/0.20 0.5 7.3 86
6×0.5 16/0.20 0.5 7.9 102
7×0.5 16/0.20 0.5 8.4 118
8×0.5 16/0.20 0.5 9.0 133
10×0.5 16/0.20 0.5 10.0 157
12×0.5 16/0.20 0.5 10.0 164
1×0.75 24/0.20 0.6 4.0 28
2×0.75 24/0.20 0.6 6.7 66
3×0.75 24/0.20 0.6 7.1 78
4×0.75 24/0.20 0.6 7.7 94
5×0.75 24/0.20 0.6 8.5 113
6×0.75 24/0.20 0.6 8.9 132
7×0.75 24/0.20 0.6 9.9 158
8×0.75 24/0.20 0.6 10.6 181
10×0.75 24/0.20 0.6 11.5 209
12×0.75 24/0.20 0.6 11.5 219
14×0.75 24/0.20 0.6 12.2 251
16×0.75 24/0.20 0.6 12.9 279
19×0.75 24/0.20 0.6 14.5 347
21×0.75 24/0.20 0.6 15.3 385
1×1 30/0.20 0.6 4.2 33
2×1 30/0.20 0.6 7.2 79
3×1 30/0.20 0.6 7.7 89
4×1 30/0.20 0.6 8.3 113
5×1 30/0.20 0.6 9.0 134
6×1 30/0.20 0.6 9.5 156
7×1 30/0.20 0.6 10.9 187
8×1 30/0.20 0.6 11.4 218
10×1 30/0.20 0.6 12.5 253
12×1 30/0.20 0.6 12.5 266
1×1.5 30/0.25 0.6 4.8 43
2×1.5 30/0.25 0.6 8.4 105
3×1.5 30/0.25 0.6 8.9 119
4×1.5 30/0.25 0.6 9.9 163
5×1.5 30/0.25 0.6 10.7 183
6×1.5 30/0.25 0.6 11.5 219
7×1.5 30/0.25 0.6 12.7 273
8×1.5 30/0.25 0.6 13.7 305
10×1.5 30/0.25 0.6 15.0 309
2×2.5 50/0.25 0.7 9.9 157
3×2.5 50/0.25 0.7 10.5 198
4×2.5 50/0.25 0.7 11.5 236
5×2.5 50/0.25 0.7 12.8 287
7×2.5 50/0.25 0.7 15.5 430
4×4 56/0.30 0.8 13.2 317
5×4 56/0.30 0.8 14.5 376

 

CALEDONIAN

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: enquiry@railway-cables.com