• Home
  • About Railway Cables European Signalling System for Rail Industry | Electrification System for Rail Industry | Basic Design for Railway Cables | Application
  • Products
  • Applications Industry | Reference List
  • Technical Information Material Properties | Standards | Customized Products | Product Certificates | Cable Glossary | FAQ
  • News & Exhibitions
  • Download
  • Link Testing Authorities | Testing Equipment Manufacturers | Magazines | Organizations | Caledonian Corporater Website
  • Sitemap
  • Contact
  • 中文

Product List

 

Traction Cables

 

Signalling & Control Cables

 

Telecom Cables

 

Power & Control Cables

 

Databus Cables

 

High Temperature Cable

 

Coaxial Cable

 

Send an enquiry to us

 

FRA 155 Single Core

Application

Single core cable with very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc.

 

Standards

  • IEC 60332-1, EN 50265-2-1 (flame retardant)
  • EN 50266-2 (non-flame propagating)

 

Construction

  • Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.
  • Insulation: Electron beam crosslinkable polyolefine copolymer.
  • Colour Code: Various colours on request.

 

 

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 16
Maximum Conductor Resistance Ω/km 85.9 57.2 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24
Voltage Rating V 450/750V (≤0.5mm²); 600/1000V (>0.5mm²)

 

Nominal Conductor Cross Section mm² 25 35 50 70 95 120 150 185 240
Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.164 0.132 0.108 0.0817
Voltage Rating V 450/750V (≤0.5mm²); 600/1000V (>0.5mm²)

 

Mechanical and Thermal Properties

  • Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing)
  • Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)
  • Short Circuit Temperature: +280℃

 

Dimensions and Weight

No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
Number and Nominal Diameter of Strands
No./mm
Nominal Insulation Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
1×0.25 19/0.13 0.5 1.5 4
1×0.34 19/0.15 0.5 1.7 5
1×0.50 16/0.20 0.5 1.8 7
1×0.75 24/0.20 0.6 2.2 10
1×1.0 30/0.20 0.6 2.5 13
1×1.5 30/0.25 0.6 2.7 20
1×2.5 50/0.25 0.7 3.4 31
1×4.0 56/0.30 0.8 4.1 46
1×6.0 84/0.30 0.9 5.2 65
1×10.0 80/0.40 1.0 6.4 110
1×16.0 126/0.40 1.1 7.5 165
1×25.0 196/0.40 1.3 9.2 250
1×35.0 276/0.40 1.3 10.4 345
1×50.0 396/0.40 1.6 12.5 550
1×70.0 360/0.50 1.6 14.7 780
1×95.0 475/0.50 1.8 16.4 1010
1×120.0 608/0.50 1.8 18.2 1280
1×150.0 756/0.50 1.9 20.8 1420
1×185.0 925/0.50 2.0 22.5 1710
1×240.0 1221/0.50 2.2 25.7 2250

 